Click on a Dataset ID in the table below to learn more, and to find
                   out who to contact about access to these data
                
                 
                   
                     Dataset ID 
                     Description 
                     Technology 
                     Samples 
                    
                  
                 
                   
                     
                       
        		               EGAD00001007580 
        	              
                       
                    		 The Genomic DNA Clean & Concentrator kit (ZYMO Research) was used to remove EDTA from the DNA samples. Sample libraries were prepared using 100 ng of input according to the KAPA HyperPlus Kit (Roche) using Unique Dual Index adapters (Integrated DNA Technologies, Inc.). Exomes were captured using the SeqCap EZ MedExome (Roche Nimblegen) according to SeqCap EZ HyperCap Library v1.0 Guide (Roche) with the xGen Universal blockers – TS Mix (Integrated DNA Technologies, Inc.). The amplified captured sample libraries were paired-end sequenced (2x100 bp) on the Novaseq 6000 platform (Illumina) and aligned to the hg19 reference genome using the Burrows-Wheeler Aligner (BWA)3, v0.7.15-r1140. 
        	              
                       
        		             
                           
                             Illumina NovaSeq 6000 
                           
                         
                        
                       209 
                      
                   
                     
                       
        		               EGAD00001007581 
        	              
                       
                    		 Sample libraries were prepped using 500 ng of input RNA according to the KAPA RNA HyperPrep Kit with RiboErase (HMR) (Roche) using Unique Dual Index adapters (Integrated DNA Technologies, Inc.). Amplified sample libraries were paired-end sequenced (2x100 bp) on the Novaseq 6000 platform (Illumina) and aligned against the human genome (hg19) using STAR v2.5.4b2. 
        	              
                       
        		             
                           
                             Illumina NovaSeq 6000 
                           
                         
                        
                       209 
                      
                   
                     
                       
        		               EGAD00001007582 
        	              
                       
                    		 ChIP-seq data were generated for a number of selected patients to investigate changes in enhancer and promoter regions. ChIP was performed as described previously with slight modifications27. Briefly, cells were crosslinked with 1% formaldehyde for 10 minutes at room temperature and the reaction was quenched with glycine at a final concentration of 0.125 M. Chromatin was sheared using the Covaris S220 focused-ultrasonicator to an average size of 250–350 bp. A total of 2.5 µg of antibody against H3K27ac (Abcam, ab4729) was added to sonicated chromatin of 2 × 106 cells and incubated overnight at 4 °C. Protein A sepharose beads (GE healthcare) were added to the ChIP reactions and incubated for 2 h at 4 °C. Beads were washed and chromatin was eluted. After crosslink reversal, RNase A and proteinase K treatment, DNA was extracted with the Monarch PCR & DNA Cleanup kit (NEB). Sequencing libraries were prepared with the NEBNext Ultra II DNA Library Prep Kit for Illumina (NEB) according to the manufacturer’s instructions. The quality of dsDNA libraries was analyzed using the High Sensitivity D1000 ScreenTape Kit (Agilent) and concentrations were assessed with the Qubit dsDNA HS Kit (Thermo Fisher Scientific). Libraries were single-end sequenced on a HiSeq 4000 (Illumina). ChIP-seq reads were aligned to the human reference genome build hg19 with bowtie 
        	              
                       
        		             
                           
                             Illumina HiSeq 4000 
                           
                         
                        
                       72 
                      
                   
                     
                       
        		               EGAD00001007583 
        	              
                       
                    		 ATAC-seq data were generated for a number of selected patients to investigate changes in enhancer and promoter regions. ATAC-seq was essentially carried out as described in31. Briefly, prior to transposition the viability of the cells was assessed and 1 × 106 cells were treated in culture medium with DNase I (Sigma) at a final concentration of 200 U ml−1 for 30 minutes at 37 °C. After Dnase I treatment, cells were washed twice with ice-cold PBS, and cell viability and the corresponding cell count were assessed. 5 × 104 cells were aliquoted into a new tube and spun down at 500 × g for 5 minutes at 4 °C, before the supernatant was discarded completely. The cell pellet was resuspended in 50 µl of ATAC-RSB buffer (10 mM Tris-HCl pH 7.4, 10 mM NaCl, 3 mM MgCl2) containing 0.1% NP-40, 0.1% Tween-20, and 1% Digitonin (Promega), and was incubated on ice for 3 minutes to lyse the cells. Lysis was washed out with 1 ml of ATAC-RSB buffer containing 0.1% Tween-20. Nuclei were pelleted at 500 × g for 10 minutes at 4 °C. The supernatant was discarded carefully and the cell pellet was resuspended in 50 µl of transposition mixture (25 µl 2× tagment DNA buffer, 2.5 µl transposase (100 nM final; Illumina), 16.5 µl PBS, 0.5 µl 1% digitonin, 0.5 µl 10% Tween-20, 5 µl H2O) by pipetting up and down six times. The reaction was incubated at 37 °C for 30 minutes with mixing before the DNA was purified using the Monarch PCR & DNA Cleanup Kit (NEB) according to the manufacturer’s instructions. Purified DNA was eluted in 20 µl elution buffer (EB) and 10 µl purified sample was objected to a ten-cycle PCR amplification using Nextera i7- and i5-index primers (Illumina). Purification and size selection of the amplified DNA were carried out with Agencourt AMPure XP beads. For purification the ratio of sample to beads was set to 1:1.8, whereas for size selection the ratio was set to 1:0.55. Purified samples were eluted in 15 µl of EB. Quality and concentration of the generated ATAC libraries were analyzed using the High Sensitivity D1000 ScreenTape Kit (Agilent) and libraries were sequenced paired-end on a NovaSeq (Illumina).
ATAC-seq reads were aligned to the human reference genome build hg19 with bowtie2 
        	              
                       
        		             
                           
                             NextSeq 500 
                           
                         
                        
                       64 
                      
                   
                     
                       
        		               EGAD00001007645 
        	              
                       
                    		 The Genomic DNA Clean & Concentrator kit (ZYMO Research) was used to remove EDTA from the DNA samples. Sample libraries were prepared using 100 ng of input according to the KAPA HyperPlus Kit (Roche) using Unique Dual Index adapters (Integrated DNA Technologies, Inc.). Exomes were captured using the SeqCap EZ MedExome (Roche Nimblegen) according to SeqCap EZ HyperCap Library v1.0 Guide (Roche) with the xGen Universal blockers – TS Mix (Integrated DNA Technologies, Inc.). The amplified captured sample libraries were paired-end sequenced (2x100 bp) on the Novaseq 6000 platform (Illumina) and aligned to the hg19 reference genome using the Burrows-Wheeler Aligner (BWA)3, v0.7.15-r1140. 
        	              
                       
        		             
                           
                             Illumina NovaSeq 6000 
                           
                         
                        
                       12 
                      
                   
                     
                       
        		               EGAD00001007646 
        	              
                       
                    		 Sample libraries were prepped using 500 ng of input RNA according to the KAPA RNA HyperPrep Kit with RiboErase (HMR) (Roche) using Unique Dual Index adapters (Integrated DNA Technologies, Inc.). Amplified sample libraries were paired-end sequenced (2x100 bp) on the Novaseq 6000 platform (Illumina) and aligned against the human genome (hg19) using STAR v2.5.4b2. 
        	              
                       
        		             
                           
                             Illumina NovaSeq 6000 
                           
                         
                        
                       12